Gas-less™ Educational GC 
The Gas-less™ Educational Model GC is configured on the ultra compact 310 
chassis and includes:
 
 
 
Upgradeable model 310 GC chassis
Catalytic Combustion ( CCD ) Detector 
Temperature Programmable column oven
Silica Gel packed column
Built-in single channel ( Model 203 ) PeakSimple Chromatography Data System

Convenient Gas-less configuration using 
internally generated air carrier gas for situations where gas cylinders may be inconvenient

The chromatogram above shows 
a mixture of three alcohols separated on a Porapak packed column at 150ºC isothermal
The chromatogram above shows 1000ppm of acetone impurity separated from hexane using a 30 meter thick film non-polar .53mm capillary column at 70ºC
The chromatogram above shows a 1ul injection of gasoline on a 60 meter .53mm capillary column programmed from 40 to 200 degrees C
The Gas-less™ Educational GC Models are ideal for undergraduate chemistry classes where the principles of chromatography are demonstrated on the same equipment the students will encounter in industry.  All Gas-less Models include a built-in "whisper quiet air compressor" and a CCD detector which detects combustible (hydrocarbon) molecules only, but which can operate on air carrier gas from the internal air compressor.  This configuration is ideal for teaching situations where compressed gas cylinders can not be used due to safety restrictions or budgetary limitations.  Because the Gas-less GCs operate on their own infinite supply of room air, GC demonstrations can be performed in the classroom instead of the lab. Unlike GC's which require helium carrier gas, with the ongoing cost of cylinder rental, storage, and gas consumption, operation of the Gas-less GC models is essentially free except for the minimal cost of electricity.  All SRI Gas-less GC's are equipped with the built-in Model 203 PeakSimple data system which provides powerful yet easy data acquisition and temperature programming for the column oven. Two Gas-less Educational Models are available. Both are identical except that the less expensive version does not include the fast cool-down fans and circuitry.  On this model, the column oven will cool-down slowly unless the oven lid is manually raised. The more expensive model with the fast cool-down fans will cool automatically at the end of the analysis from 250ºC to 50ºC in less than 5 minutes.

0310-1005 Gas-less Educational GC with manual cool-down  $4295.00
0310-1006 Gas-less Educational GC with fast cool-down   $4995.00
 