Ten
Position Method 5030 Purge & Trap Autosampler
|
87
|
|
|
|
|
| VOC
Screening System |
|
- CCD Detector
- Heated
Headspace Sleeve
- No Sample
Preparation necessary
- Quick
& easy Total VOC measurements
- Built-in
"whisper quiet" air compressorno gases needed!
- 1 channel
PeakSimple Data System
...on the space-saving 110 chassis
|
|
The VOC Screening
System uses dynamic thermal stripping to detect VOCs in water, soil,
mud, sludge, and crud. It is equipped with a heated headspace sleeve
to strip the VOCs from the sample, and a Catalytic
Combustion Detector to detect the total VOCs down to 0.05%.
Compact and convenient, this instrument is ideal for field screening
or testing. With the built-in air compressor
to provide an infinite supply of air for the purge gas and the CCD
detector, no cylinders are used. Configured on the ultra compact
110 chassis, the VOC Screening System travels easily and will fit
virtually anywhere.
The headspace
sleeve is heated from ambient to 125oC, accepts standard
40mL VOA vials, and eliminates the need for sample preparation.
Because the CCD detector is kept warm, it can tolerate the high
water content present in the headspace from the heated sample.
|
|
|
0110-0100
|
VOC
Screening System
|
$
4,995.00
|
|
|
| Method
5035 VOA Vial Purge Head Retrofit |
 |
- Affordable
EPA Method 5035 Compliance
- Retrofit
Tekmar, O.I., and SRI Purge & Trap systems
- Thermostatted
and Mechanically Agitated VOA vial sleeve
- Heated
Transfer Line
|
|
|
The SRI Method 5030
VOA Vial Purge Head Retrofit is designed for all models of SRI, Tekmar,
and O.I. purge and trap systems. For users who do not have sufficient
samples to justify the purchase of a Method 5035 autosampler, but who
nonetheless need Method 5035 capability on their existing purge and trap
system, this affordable retrofit is the solution.
It connects ot the host with a single 1/16" tube for purge gas in,
and a heated transfer line for analyte-laden purge gas out. A single contact
closure from the host's data system or GC initiates the mechanical agitation
of the heated VOA vial sleeve, as required by Method 5035.
The Method 5035 VOA
Vial Purge Head Retrofit simply replaces the existing purge vessel, whether
that vessel is the fritted glass type or the needle sparger type, and
whether the purge vessel is mounted on the purge and trap mainframe or
a single position ona multi-position purge and trap autosampler (such
as the Tekmar 2016 ALS unit).
|
|
8680-0052
|
Method
5035 VOA Vial Purge Head Retrofit
|
$
3,495.00
|
|
|
Ten
Position Method 5030 Purge & Trap Autosampler
Online Sampler for Purge & Trap |
87
|
|
|
|
|