TO-14
Air Monitoring GC System
|
22-23
|
|
|
|
|
|
- Dual trap
TO-14 air concentrator
- PID and combination FID/DELCD detectors
- Vacuum pump with PeakSimple controlled Interface
- Built-in "whisper quiet" air compressor
- 6 channel PeakSimple data system
- 60-meter capillary column
...on the compact 8610C chassis
|
|
|
For
TO-14 analysis and ambient air analyses of all types, this GC has
everything you need in a compact, easy-to-transport package. |
|
| The dual trap
TO-14 Air Concentrator is similar to our Purge
& Trap, but it has a gas inlet instead of a liquid purge vessel
(a liquid purge head can be added if required). The innovative dual
trap design results in more efficient trapping and desorption than
single trap designs, especially for early eluting peaks such as vinyl
chloride. Please see page 72 for more information
on the TO-14 Air Concentrator. |
 |
|
The 60-meter capillary
column is the newest unbreakable, fused silica-lined, stainless steel
technology, which gives good separation of the TO-14 analytes with short
run times. The PeakSimple data system controls
and sequences the entire analysis, collecting the data from the three
detectors, loading and desorbing the traps, then calculating and printing
the results.
Since it is small
enough to take on-site for real-time measurements, you can perform the
analysis right at the source, avoiding the need for expensive, labor-intensive
canister sampling. The vacuum pump interface
allows the data system to turn the external vacuum pump ON/OFF under
PeakSimple control. The vacuum pump is used to draw ambient air through
the traps for a precise amount of time, thus enabling the system to
sample unattended. The built-in air compressor
eliminates the hassle of transporting bulky air cylinders by providing
an endless supply of combustion air for the FID/DELCD
combination detector.
|
|
The DELCD
is completely selective for compounds containing chlorine and/or
bromine. Other analytes do not respond at all, even at very high
levels. The DELCD actually operates on the FID
exhaust gases. All contaminants are pre-combusted by the FID to
CO2 and H2O
before reaching the DELCD.
The first few
peaks in the 8021 standard, especially vinyl chloride, are of special
interest to many analysts. This chromatogram shows the expanded
detail of the first few peaks (the VOC gases) in the analysis shown
above. Note the exceptionally good resolution and peak shape delivered
by SRI's dual trap technology.
|
 |
|
|
|
8610-0114
|
TO-14 Air
Monitoring GC System
|
$
23,169.00
|
|
(VOLTAGE:
for 110VAC use 8610-0114-1 for 230VAC use 8610-0114-2)
|
|
|
|
|
|
TO-14 Air
Monitoring GC System
|
22-23
|
|
|
|